dr_tengine.py

dr_tengine.py is a combination T-engine and recording pipeline for the voltage beam mode. This pipeline captures packetized beam data from the digital system, down selects the frequency coverage to match what is requested by the observer, converts the data back into the time domain, and writes raw DRX files.

Structure

The pipeline is written in the Bifrost framework and has four blocks: CaptureOp, ReChannelizerOp, TEngineOp, and WriterOp.

  • CaptureOp - This is the data capture block which is responsible for capturing the beam packets from the digital system, ordering them in time and frequency, and writing the organized data to a Bifrost ring.

  • ReChannelizerOp - This reads in the beam data and performs an inverse FFT followed by an FFT to change the channel width of the data to 50 kHz.

  • TEngineOp - This reads in the re-channelized data, down selects the frequency range, and performs an inverse FFT to create time domain voltage data.

  • WriterOp - This reads in time domain data and writes raw DRX files to disk.

The pipeline is designed such that there is one pipeline per voltage beam. For the expected number un-averaged beams created by the digital system this equates to 2 pipeline instances.

Control Commands

The dr_tengine.py pipeline supports six commands: ping, sync, record, cancel, delete, and drx.

  • ping - This command simply replies which is helpful to see if the pipeline is responsive. There are no required or optional arguments. Returns a response of “pong”.

  • sync - This command sets the system time via NTP. The required arguments to this command are:

    • server - a NTP server name or IP address to sync against.

    There are no optional arguments. The command returns the sync status.

  • record - This schedules a recording to take place. The required arguments to this command are:

    • start_mjd - an integer MJD value for when the recording will start,

    • start_mpm - an integer number of milliseconds past midnight value on the MJD specified in start_mjd for when the recording will start, and

    • duration_ms - the number of milliseconds to record data for.

    There are no optional arguments. The command returns the name of the file that will be written. The name will be of the format “<mjd>_<MCS sequence id>”.

  • cancel - This cancels a previously scheduled or active recording. The

    required arguments to this command are:

    • queue_number - an entry number in the recording queue to cancel.

    There are no optional arguments. The command returns the base name for the files that were to have been written/were written that is associated with the queue entry.

  • delete - This deletes a file from the recording directory. The required arguments to this command are:

    • file_number - an entry number in the file list of the recording directory.

    There are no optional arguments. The command returns the name of the file that was deleted.

  • drx - This controls the down selection in frequency for the T-engine as as well as the quantization gain when moving to 4+4-bit complex integers for the output. The required arguments to this command are:

    • beam - an integer of the voltage beam number of control,

    • tuning - an integer of the tuning number, 1 or 2, within the voltage beam to control,

    • central_freq - the central frequency of the tuning in Hz,

    • filter - an integer for the output bandwidth code, 7 = 19.6 MHz, and

    • gain - an integer for the quantization gain.

    There is a single optional argument of subslot which controls when the command is implemented within the second. If not specified the default of 0 is used.

Monitoring Points

There are several monitoring points for the pipeline. All monitoring points live under the etcd key “/mon/drt#”, where # is the power beam number that is being recorded.

  • /mon/drt#/bifrost

    • pipeline_lag - The lag between the system time and the timestamps for data in the pipeline.

    • max_acquire - The maximum span/gulp acquire time across all blocks in the pipeline.

    • max_process - The maximum span/gulp processing time across all blocks in the pipeline.

    • max_reserve - The maximum span/gulp reserve time across all blocks in the pipeline.

    • rx_rate - Packet capture rate for the pipeline.

    • rx_missing - Fraction of missing packets for the pipeline.

  • /mon/drt#/storage

    • active_disk_size - The size of the disk where the recording directory resides.

    • active_disk_free - The amount of free space on the disk where the recording directory resides.

    • active_directory - The current recording directory.

    • active_directory_size - The size of all files in the recording directory.

    • active_directory_count - The number of files in the recording directory.

  • /mon/drt#/summary - An overall status of the pipeline. Possible values are “normal”, “warning”, and “error”.

  • /mon/drt#/info - A more detailed explanation of the summary condition.

Data Format

The DRX format is a Mark 5C-based packetized format for storing complex voltage timeseries data. The header for these packets are defined as:

DRX packet header

The only portion of this header that is saved to disk by dr_tengine.py is the yellow Mark 5C portion in the above image. Each data frame will contain data of one polarization (X or Y), one DRX tuning, and 4096 samples stored as 4+4 bit complex integers (signed two’s complement). The total size of a data packet is 4128 bytes. The Mark 5C header will include an ID field that identifies which polarization and tuning is associated with the data, as described in the table below.

The Mark 5C header will include Frame Count and Seconds Count fields for compatibility purposes but both of these fields will always be set to zero. The Data Frame header will include a Decimation Factor field that describes the decimation factor used in producing the output data. The output sample rate is fs/Decimation Factor. The Data Frame header will also include a Time Offset field that provides the known time offset (Tnom in LWA Memo 151), in units of 1/fs since the beginning of the second. The Data Frame will include a Time field (t1 in LWA Memo 151) in units of 1/fs since 1970 January 1 00:00 UTC. For the i-th sample of the frame, the time at that sample is related to the frame time tag through:

t_i = \mbox{time} + (i-1) \times \frac{\mbox{DecimationFactor}}{f_s}.

The Data Frame will also include a tuning word, a unsigned 32-bit integer, which specifies the central tuning of the DRX data. This tuning word, w, can be converted to a frequency in Hz via:

f = \frac{w}{2^{32}} f_s,

where fs is defined as 196 MHz. The status/flags field in the Data Frame is currently unimplemented in the DRX firmware and is set to zero for all frames.

Each sample is 8 bits total (4 bits I and 4 bits Q). Therefore 4096 samples require 4096 bytes. Inside each 32-bit word, the data will be arranged in the following order (from MSB to LSB):

I0 (bits 31-28), Q0 (bits 27-24), I1 (bits 23-20), Q1 (bits 19-16),
I2 (bits 15-12), Q2 (bits 11-8), I3 (bits 7-4), Q3 (bits 3-0).

The numbers in paraphrases are the bits within each sample such that 0 is the LSB.

DRX_ID Numbering

DRX_BEAM

DRX_TUNING

Polarization

DRX_ID

1

1

X

9

1

1

Y

137

1

2

X

17

1

2

Y

145

2

1

X

10

2

1

Y

138

2

2

X

18

2

2

Y

146

3

1

X

11

3

1

Y

139

3

2

X

19

3

2

Y

147

4

1

X

12

4

1

Y

140

4

2

X

20

4

2

Y

148

DRX Numbering is as follows: DRX_ID is an unsigned 8-bit integer.

  • Bits 0-2 are used to represent DRX_BEAM,

  • bits 3-5 are used to represent DRX_TUNING,

  • bit 6 is reserved for future use, and